Engine Stranglers

MES5MS
  • MES3
  • MES5
Liquip

Liquip offers a range of mechanical engine stranglers that can shut down the engine of fuel delivery trucks in an emergency situation such as roll over.

The engine strangler can be pneumatically or manually actuated to stop the engine in case of diesel runaway, and is easily re-set for continued use once activated.

The engine strangler can also be actuated by the rollover sensor via a solenoid valve. This provides a complete system of engine protection and electrical isolation for maximum vehicle safety.

Share this product
  • 100% reusable. Once installed, it never needs replacement, no matter how many times it is used to save the vehicle.
  • Manual, cable or air operated for added convenience.
  • Available in both 3" and 5"
     

Minimum operating pressure
400 kPa.

Maximum operating pressure
900 kPa.

Air fittings
2 x 1/8” BSP.

Maintenance
It is recommended that the valve operation be checked, using all the methods of actuation which may be fitted to particular vehicle, at normal service intervals.

MES3:3” Mechanical Engine Strangler.

MES5: 5” Mechanical Engine Strangler.

MES5MS: Mechanical Engine Strangler Air/Mine Spec (contact Liquip for technical data).

 

RS400: Liquip Rollover Sensor.